The MPLS WG Archive[Date Prev][Date Next][Thread Prev][Thread Next] [Date Index][Thread Index][Author Index][Subject Index] MPLS fast reroute with facility protection technique !!
Hi, In facility backup technique, a PLR may need to send same PATH message (as the LSP being protected), before primary LSP failure, over bypass tunnel if the MP does not support platform labels (label space 0). Now, in this situation what happens if the protected LSP fails ? a) Should PLR continue to send the original PATH msg (for label discovery) over the bypass tunnel and also signal backup LSP over the bypass tunnel using a modified PATH message with a different sender template as decribed in the draft. or b) Should it stop sending the original (label discovery) PATH message and just start sending out the modified PATH message (different sender template) over the bypass tunnel (for signaling backup LSP). Thanks in advance Manoj |
|